Dallas City Council is scheduled to vote Dec. 9 on a building code change that would let some apartment buildings of up to six stories go up with one stairway instead of two (via City of Dallas). The item, file 26-3699A, amends Chapter 53 of the city code, the Dallas Building Code, and is listed as agenda-ready for that meeting.
For anyone who builds small multifamily, that's a real shift. Under the International Building Code, apartment buildings taller than three stories generally need two stairwells, according to a Texas Senate bill analysis. That second stair eats floor space and pushes designs toward wide buildings with a long central hallway, which tend to pencil out mainly on bigger lots and at higher density.
The Dallas change traces back to Senate Bill 2835, which the Legislature passed in 2025 and which took effect Sept. 1, 2025. The law doesn't require cities to do anything. It says a municipality "may authorize" a single stairway in an apartment building, but only when the building meets every item on a list of 14 conditions.
Those conditions are where the design work lives. Under the state law, a qualifying building can have no more than six stories above grade plane, can't be a high-rise under the IBC, and can't have more than four dwelling units on any floor. Interior exit stair enclosures need at least a two-hour fire resistance rating with no elevator opening into them, and each interior exit stairway needs sprinklers that meet NFPA 13 for combustible stairways.
Distances are tight, too. No unit's entry door can sit more than 20 feet from an exit stairway, and exit access travel distance tops out at 125 feet. Each floor needs a corridor rated for at least one hour running from the unit doors to the interior stair, plus emergency escape and rescue openings that meet IBC Section 1031 on every floor served by a single exit.
A few smaller items could trip up a plan set: no electrical receptacles inside an interior exit stairway, no exit serving two or more units that discharges through a different occupancy such as an accessory parking garage, and an automatic smoke and fire detection system that triggers occupant notification under IBC Section 907.5. That detection has to cover common spaces, corridors serving units, laundry, mechanical and storage rooms, and the stair landings.
On the city side, staff wrote that the Planning and Development Department drafted the amendment in response to SB 2835 and that it addresses automatic sprinklers, fire-rated stair enclosures, smoke detection, emergency egress and fire department access. Staff held workgroup meetings and gathered stakeholder feedback, according to the agenda item, which describes the aim as "greater flexibility in multifamily residential building design" while keeping fire and life safety protections in place.
The city's Building Inspection Advisory, Examining and Appeals Board approved sending the amendment to council on Nov. 17, 2026, and the Economic Development Committee is set to be briefed by memorandum on Dec. 1, per the agenda item. The ordinance includes a penalty of up to $2,000, and the city lists no cost to its own budget. The item is tagged as being in alignment with ForwardDallas. The summary doesn't say when the change would take effect if approved.
Dallas wouldn't be the first big Texas city to move on this. Austin's council approved single-stair rules on a 10-1 vote in April 2025, allowing buildings up to five stories with four units per floor, Community Impact reported. The Senate bill analysis lists Habitat for Humanity in Dallas and Austin and the Dallas Housing Coalition among the state bill's supporters, and notes the sponsor's claim that single-stair buildings can reach 95 percent floor plate efficiency.
Why it matters for Contractors
Small-lot multifamily is where this lands hardest. A single stair can make a four-to-six-story building work on an infill lot that would never fit two stairwells and a double-loaded corridor. If you build small apartment projects in Dallas, or want to, this could open up sites you'd have passed on before.
It isn't a shortcut, though. The 20-foot and 125-foot distance limits, the two-hour stair enclosure, the sprinkler and alarm requirements and the four-units-per-floor cap shape the floor plan from the first sketch. Get your architect and fire protection sub involved before you commit to a lot price, and make sure framing and electrical crews know about the one-hour corridors and the no-receptacle rule in the stair.
Nothing changes until council acts. Keep an eye on the Dec. 9 agenda, and if the ordinance passes, work from the adopted Dallas text, since that's what the city's plan reviewers will check your drawings against.